The 35/25 Silver Vacuum Jacketed Oldershaw Mixing Column is a used laboratory glass column designed for liquid mixing, vapor-liquid contact, thermal isolation, and chemical process support workflows. Constructed from borosilicate glass, this Oldershaw-style mixing column features closely spaced internal protrusions that help mix liquid samples as they flow through the column.
Unlike a traditional plated Oldershaw distillation column, which uses perforated trays and downcomers to create theoretical stages for fractional separation, this column is designed as a fractional mixing column. The internal protrusions increase contact and flow disruption, helping improve mixing behavior in compatible laboratory setups.
This column includes a silver vacuum jacket, which helps reduce heat transfer by radiation. That makes it useful for workflows where more stable internal column temperatures can support better process consistency, controlled liquid movement, and reduced thermal variation.
For related chemical processing equipment, browse HiTechTrader’s used laboratory equipment, laboratory reactors, laboratory pumps, and analytical instruments.
This silver vacuum jacketed Oldershaw mixing column is designed to improve liquid interaction as material flows through the column. The internal protrusions are positioned close together, helping create turbulence, contact, and mixing within the glass column.
This makes the column useful for workflows involving:
The internal protrusion design gives laboratories more mixing activity than a plain glass tube while maintaining clear visibility through the borosilicate glass body.
The silver coating on this vacuum jacketed Oldershaw style column is used primarily to reduce heat transfer by radiation. In temperature sensitive workflows, this can help limit heat gain or heat loss from the surrounding laboratory environment.
A silvered vacuum jacket helps support:
For laboratories performing chemical processing, solvent handling, or vapor-liquid contact work, vacuum jacketed glassware can help improve consistency compared with non jacketed glass columns.
This column is configured with a 35/25 top joint and a 50/32 bottom ball joint, making it useful for specialized or custom laboratory glassware assemblies.
The mixed joint configuration may support:
The 50/32 ball joint bottom allows more flexible alignment than a rigid taper joint, which can be helpful when integrating the column into larger or custom glassware systems.
This used Oldershaw-style mixing column is constructed from borosilicate glass, a preferred material for laboratory glassware because it provides chemical resistance, visibility, and thermal stability.
Borosilicate glass benefits include:
This makes the column a practical option for laboratories needing specialized glassware for controlled liquid mixing or process support applications.
This column includes a corrugated vacuum jacket or expansion bellows design. Expansion bellows help accommodate thermal expansion and contraction during heating and cooling cycles, reducing stress on the glass and supporting repeated laboratory use.
Benefits of the corrugated vacuum jacket / expansion bellows include:
For labs using this column repeatedly in temperature sensitive setups, the expansion bellows design can help support dependable operation.
| Specification | Details |
|---|---|
| Product Type | Silver vacuum jacketed Oldershaw mixing column |
| Condition | Used |
| Column Style | Borosilicate glass fractional mixing column |
| Internal Design | Closely spaced internal protrusions |
| Column Inside Diameter | 1 in / 25.4 mm |
| Column Outside Diameter | 2 in / 50.8 mm |
| Top Joint | 35/25 |
| Bottom Joint | 50/32 ball joint |
| Overall Length | 22.5 in / 571.5 mm |
| Construction | Borosilicate glass |
| Silver Vacuum Jacket | Yes |
| Corrugated Vacuum Jacket / Expansion Bellows | Yes |
| Primary Use | Liquid mixing, vapor-liquid contact, thermal isolation, chemical process support |
The 35/25 Silver Vacuum Jacketed Oldershaw Mixing Column is suitable for laboratories that need specialty glassware for liquid mixing, vapor liquid interaction, or process-support workflows.
Common applications include:
This column is especially useful for labs that need internal mixing features inside a thermally isolated borosilicate glass column.
Closely spaced internal protrusions help increase contact and mixing as liquid flows through the column.
Helps reduce radiant heat transfer and supports more stable internal conditions.
Helps reduce glass stress during thermal cycling and repeated laboratory use.
Supports integration into specialized or custom laboratory glassware assemblies.
Provides chemical resistance, visibility, and thermal stability for laboratory workflows.
Offers specialty vacuum jacketed glassware at a more cost effective price than many new custom glass components.
HiTechTrader helps laboratories source scientific, analytical, chemical processing, and laboratory equipment for research, testing, purification, process development, and education. This used 35/25 Silver Vacuum Jacketed Oldershaw Mixing Column is a practical option for laboratories that need specialty glassware for mixing, vapor liquid contact, or thermal isolation workflows.
Buyers can also explore related equipment categories, including:
For laboratories building a complete chemical processing workflow, this column can be paired with compatible reactors, condensers, adapters, receiving vessels, vacuum systems, heating equipment, pumps, GC-MS instruments, and analytical tools.
HiTechTrader offers this used 35/25 Silver Vacuum Jacketed Oldershaw Mixing Column for laboratories needing specialty glassware for liquid mixing, vapor liquid contact, thermal isolation, or process-support applications.
This column is a strong fit for chemical process research, solvent handling, liquid sample mixing, vapor transfer, organic chemistry experiments, and small scale workflow development.
Contact HiTechTrader to request pricing, verify joint compatibility, or source additional laboratory glassware and chemical processing equipment for your setup.
FAQs
A silver vacuum jacketed Oldershaw mixing column is laboratory glassware designed to improve liquid contact, mixing, and thermal stability during chemical workflows. The internal protrusions help mix liquid as it flows through the column, while the silver vacuum jacket helps reduce radiant heat transfer.
An Oldershaw distillation column typically uses perforated plates or trays to create theoretical stages for fractional separation. An Oldershaw mixing column uses internal protrusions or mixing features to improve contact and flow disruption rather than staged distillation separation.
The internal protrusions help disrupt liquid flow and increase contact as the sample moves through the column. This can improve mixing, interaction, and contact between liquid phases in compatible laboratory workflows.